INITSTAT

         Initialization status used to indicate completion of hardware memory initialization done through CTRL.INITA / CTRL.INITB
      
Module Instance Base Address Register Address
sdm_ecc_nand_r_ecc_registerBlock 0xFFA21000 0xFFA2100C

Size: 32

Offset: 0xC

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

INITCOMPLETEB

0x0

Reserved

INITCOMPLETEA

0x0

INITSTAT Fields

Bit Name Description Access Reset
8 INITCOMPLETEB
Indicate hardware memory initialization has completed on PORTB.
RW 0x0
0 INITCOMPLETEA
Indicate hardware memory initialization has completed on PORTA.
RW 0x0