SMMU_CB24_RESUME

         The Transaction Resume is used to resume operation of a transaction that is stalled because of an existing fault condition.
      
Note: For register and programming information, please refer to the Arm® CoreLink™ MMU System Memory Management Unit Technical Reference Manual.
Module Instance Base Address Register Address
i_aps_smmu_secure_registers 0xFA000000 0xFA038008

Size: 32

Offset: 0x38008

Access: WO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

TnR

WO 0x0