SMMU_CB12_CONTEXTIDR

         Identifies the current process identifier and the current address space identifier
      
Note: For register and programming information, please refer to the Arm® CoreLink™ MMU System Memory Management Unit Technical Reference Manual.
Module Instance Base Address Register Address
i_aps_smmu_secure_registers 0xFA000000 0xFA02C034

Size: 32

Offset: 0x2C034

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

PROCID

RW 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

PROCID

RW 0x0

ASID

RW 0x0