bridge_iocb0_sprt_11_67_as_err
These error status bits record the first error event and have to be cleared by writing a 1'b0 before new errors are recorded. e0 - e7 are relative to AR channel. e16 - e23 are WR channel counter parts.
Module Instance | Base Address | Register Address |
---|---|---|
i_ccu_noc_registers | 0xF7000000 | 0xF7049E00 |
Size: 64
Offset: 0x49E00
Access: RW
Access mode: SECURE | PRIVILEGEMODE
Note: The processor must make a secure, privileged bus access to this register. You can configure processor mode settings in the control registers of the ARM Cortex-A53 MPcore processor. For more information about processor modes, please refer to the ARM Infocenter.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 |
UNSD_63_33 RO 0x0 |
|||||||||||||||
47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
UNSD_63_33 RO 0x0 |
E32 RW 0x0 |
||||||||||||||
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
UNSD_31_20 RO 0x0 |
E19 RW 0x0 |
E18 RW 0x0 |
E17 RW 0x0 |
E16 RW 0x0 |
|||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
UNSD_15_5 RO 0x0 |
E4 RW 0x0 |
E3 RW 0x0 |
E2 RW 0x0 |
E1 RW 0x0 |
E0 RW 0x0 |
bridge_iocb0_sprt_11_67_as_err Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
63:33 | UNSD_63_33 |
|
RO | 0x0 |
32 | E32 |
1'b1: Traffic sent to a noc layer which is power gated |
RW | 0x0 |
31:20 | UNSD_31_20 |
|
RO | 0x0 |
19 | E19 |
1'b1: Write command modified: A write command which was marked as non-modifiable was modified by the slave bridge |
RW | 0x0 |
18 | E18 |
1'b1: Unknown write response destination: BID from write response produces a destination which is not present in the routing table |
RW | 0x0 |
17 | E17 |
1'b1: Write slave error response: Slave error response received from slave device for write command |
RW | 0x0 |
16 | E16 |
1'b1: Write decode error response: Decode error response received from slave device for write command |
RW | 0x0 |
15:5 | UNSD_15_5 |
|
RO | 0x0 |
4 | E4 |
1'b1: Read command modified: A read command which was marked as non-modifiable was modified by the slave bridge |
RW | 0x0 |
3 | E3 |
1'b1: Interleaved read response: Interleaved read response. This can occur if interleaved read response is received from a slave device for which a de-interleaver was not specified |
RW | 0x0 |
2 | E2 |
1'b1: Unknown read response destination: RID from read response produces a destination which is not present in the routing table |
RW | 0x0 |
1 | E1 |
1'b1: Read slave error response: Slave error response received from slave device for read command |
RW | 0x0 |
0 | E0 |
1'b1: Read decode error response: Decode error response received from slave device for read command |
RW | 0x0 |