IC_SS_SCL_LCNT

         Name: Standard Speed I2C Clock SCL Low Count Register
Size: 16 bits
Address Offset: 0x18
Read/Write Access: Read/Write
Dependencies: This register is not applicable  when IC_ULTRA_FAST_MODE=1

      
Module Instance Base Address Register Address
sdm_i2c_0_DW_apb_i2c_addr_block0 0xFF8D0100 0xFF8D0118
sdm_i2c_1_DW_apb_i2c_addr_block1 0xFF8D0200 0xFF8D0218

Size: 32

Offset: 0x18

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

RSVD_IC_SS_SCL_LOW_COUNT

RO 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

IC_SS_SCL_LCNT

RW 0x24C

IC_SS_SCL_LCNT Fields

Bit Name Description Access Reset
31:16 RSVD_IC_SS_SCL_LOW_COUNT
Reserved bits - Read Only
RO 0x0
15:0 IC_SS_SCL_LCNT
This register must be set before any I2C bus transaction can take place to
ensure proper I/O timing. This register sets the SCL clock low period
count for standard speed. 
This register can be written only when the I2C interface is disabled which
corresponds to the IC_ENABLE[0] register being set to 0. Writes at other
times have no effect.
The minimum valid value is 8; hardware prevents values less than this
being written, and if attempted, results in 8 being set. For designs with
APB_DATA_WIDTH = 8, the order of programming is important to
ensure the correct operation of DW_apb_i2c. The lower byte must be
programmed first, and then the upper byte is programmed.
When the configuration parameter IC_HC_COUNT_VALUES is set to 1,
this register is read only.
Reset value: IC_SS_SCL_LOW_COUNT configuration parameter
RW 0x24C