rdwr_en_lo_cnt

Read/Write Enable low pulse width
Module Instance Base Address Register Address
nandregs 0xFFB80000 0xFFB801F0

Offset: 0x1F0

Access: RW

Important: To prevent indeterminate system behavior, reserved areas of memory must not be accessed by software or hardware. Any area of the memory map that is not explicitly defined as a register space or accessible memory is considered reserved.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

value

RW 0x12

rdwr_en_lo_cnt Fields

Bit Name Description Access Reset
4:0 value

Number of nand_mp_clk cycles that read or write enable will kept low to meet the min Trp/Twp parameter of the device. The value in this register plus rdwr_en_hi_cnt register value should meet the min cycle time of the device connected. The default value is calculated assuming the max nand_mp_clk time period of 4ns to work with ONFI Mode 0 mode of 100ns device cycle time. This assumes a 1x/4x clocking scheme.

RW 0x12