parityinj
Module Instance | Base Address | Register Address |
---|---|---|
sysmgr | 0xFFD08000 | 0xFFD0801C |
Offset: 0x1C
Access: RW
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
btac_1 RW 0x0 |
btac_0 RW 0x0 |
ghb_1 RW 0x0 |
ghb_0 RW 0x0 |
ictag_1 RW 0x0 |
ictag_0 RW 0x0 |
icdata_1 RW 0x0 |
icdata_0 RW 0x0 |
maintlb_1 RW 0x0 |
maintlb_0 RW 0x0 |
dcouter_1 RW 0x0 |
dcouter_0 RW 0x0 |
dctag_1 RW 0x0 |
dctag_0 RW 0x0 |
dcdata_1 RW 0x0 |
dcdata_0 RW 0x0 |
parityinj Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
15 | btac_1 | If 1, injecting parity error to BTAC RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
14 | btac_0 | If 1, injecting parity error to BTAC RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
13 | ghb_1 | If 1, injecting parity error to GHB RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
12 | ghb_0 | If 1, injecting parity error to GHB RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
11 | ictag_1 | If 1, injecting parity error to Instruction Cache Tag RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
10 | ictag_0 | If 1, injecting parity error to Instruction Cache Tag RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
9 | icdata_1 | If 1, injecting parity error to Instruction Cache Data RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
8 | icdata_0 | If 1, injecting parity error to Instruction Cache Data RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
7 | maintlb_1 | If 1, injecting parity error to Main TLB RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
6 | maintlb_0 | If 1, injecting parity error to Main TLB RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
5 | dcouter_1 | If 1, injecting parity error to Data Cache Outer RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
4 | dcouter_0 | If 1, injecting parity error to Data Cache Outer RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
3 | dctag_1 | If 1, injecting parity error to Data Cache Tag RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
2 | dctag_0 | If 1, injecting parity error to Data Cache Tag RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
1 | dcdata_1 | If 1, injecting parity error to Data Cache Data RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |
0 | dcdata_0 | If 1, injecting parity error to Data Cache Data RAM.The field array index corresponds to the CPU index. |
RW | 0x0 |