stat
Module Instance | Base Address | Register Address |
---|---|---|
clkmgr | 0xFFD04000 | 0xFFD04014 |
Offset: 0x14
Access: RO
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
busy RO 0x0 |
stat Fields
Bit | Name | Description | Access | Reset | ||||||
---|---|---|---|---|---|---|---|---|---|---|
0 | busy | This read only bit indicates that the Hardware Managed clock's state machine is active. If the state machine is active, then the clocks are in transition. Software should poll this bit after changing the source of internal clocks when writing to the BYPASS, CTRL or DBCTRL registers. Immediately following writes to any of these registers, SW should wait until this bit is IDLE before proceeding with any other register writes in the Clock Manager. The reset value of this bit is applied on a cold reset; warm reset has no effect on this bit.
|
RO | 0x0 |