Probe_MPU_main_Probe_StatAlarmMin

         
      
Module Instance Base Address Register Address
i_noc_mpu_m0_Probe_MPU_main_Probe 0xFFD15000 0xFFD1502C

Offset: 0x2C

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

STATALARMMIN

RW 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

STATALARMMIN

RW 0x0

Probe_MPU_main_Probe_StatAlarmMin Fields

Bit Name Description Access Reset
31:0 STATALARMMIN
Register StatAlarmMin contains the minimum count value used in statistics alarm comparisons. The number of bits is equal to twice the value set forparameter wStatisticsCounter. When parameter statisticsCounterAlarm is set to False, StatAlarmMin is reserved.
RW 0x0