Probe_emacs_main_Probe_MainCtl

         Register MainCtl contains probe global control bits. The register has seven bit fields:
      
Module Instance Base Address Register Address
i_noc_mpu_m0_Probe_emacs_main_Probe 0xFFD14400 0xFFD14408

Offset: 0x8

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

FILTBYTEALWAYSCHAINABLEEN

RW 0x0

INTRUSIVEMODE

RO 0x0

STATCONDDUMP

RW 0x0

ALARMEN

RW 0x0

STATEN

RW 0x0

PAYLOADEN

RW 0x0

TRACEEN

RW 0x0

ERREN

RW 0x0

Probe_emacs_main_Probe_MainCtl Fields

Bit Name Description Access Reset
7 FILTBYTEALWAYSCHAINABLEEN
When set to 0, filters are mapped to all statistic counters when counting bytes or enabled bytes. Therefore, only filter events mapped to even counters can be counted using a pair of chained counters.When set to 1, filters are mapped only to even statistic counters when counting bytes or enabled bytes. Thus events from any filter can be counted using a pair of chained counters.
RW 0x0
6 INTRUSIVEMODE
When set to 1, register field IntrusiveMode enables trace operation in Intrusive flow-control mode. When set to 0, the register  enables trace operation in Overflow flow-control mode
RO 0x0
5 STATCONDDUMP
When set, register field StatCondDump enables the dump of a statistics frame to the range of counter values set for registers StatAlarmMin, StatAlarmMax, and AlarmMode. This field also renders register StatAlarmStatus inoperative. When parameter statisticsCounterAlarm is set to False, the StatCondDump register bit is reserved.
RW 0x0
4 ALARMEN
When set, register field AlarmEn enables the probe to collect alarm-related information. When the register field bit is null, both TraceAlarm and StatAlarm outputs are driven to 0.
RW 0x0
3 STATEN
When set to 1, register field StatEn enables statistics profiling. The probe sendS statistics results to the output for signal ObsTx. All statistics counters are cleared when the StatEn bit goes from 0 to 1. When set to 0, counters are disabled.
RW 0x0
2 PAYLOADEN
Register field PayloadEn, when set to 1, enables traces to contain headers and payload. When set ot 0, only headers are reported.
RW 0x0
1 TRACEEN
Register field TraceEn enables the probe to send filtered packets (Trace) on the ObsTx observation output.
RW 0x0
0 ERREN
Register field ErrEn enables the probe to send on the ObsTx output any packet with Error status, independently of filtering mechanisms, thus constituting a simple supplementary global filter.
RW 0x0