enr

         Write One to Clear corresponding fields in Enable Register.
      
Module Instance Base Address Register Address
i_clk_mgr_mainpllgrp 0xFFD04040 0xFFD04050

Offset: 0x10

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

hmcpllrefclken

RW 0x1

s2fuser0clken

RW 0x1

cstimerclken

RW 0x1

csclken

RW 0x1

l4spclken

RW 0x1

l4mpclken

RW 0x1

l4mainclken

RW 0x1

mpuclken

RW 0x1

enr Fields

Bit Name Description Access Reset
7 hmcpllrefclken
Enables clock hmc_pll_ref_clk output
RW 0x1
6 s2fuser0clken
Enables clock s2f_user0_clk output
RW 0x1
5 cstimerclken
Enables Debug Timer Clock output (cs_timer_clk)
RW 0x1
4 csclken
Enables Debug Clock outputs (cs_at_clk, cs_pdbg_clk and cs_trace_clk)
RW 0x1
3 l4spclken
Enables clock l4_sp_clk output
RW 0x1
2 l4mpclken
Enables clock l4_mp_clk output
RW 0x1
1 l4mainclken
Enables clock l4_main_clk output
RW 0x1
0 mpuclken
Enable for MPU Clock Group (mpu_clk, mpu_l2ram_clk and mpu_periph_clk).
RW 0x1