AUTOWB_DROP_CNTREG

         Maximum counter value for AUTOWB correction interrupt
      
Module Instance Base Address Register Address
ecc_hmc_ocp_slv_block 0xFFCFB000 0xFFCFB140

Offset: 0x140

Access: RW

Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

CNT

0x1

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

CNT

0x1

AUTOWB_DROP_CNTREG Fields

Bit Name Description Access Reset
31:0 CNT
Compare value for the internal autoWB correction count.
This register sets the value to compare with the autoWB internal counter. Software should write to this register before enabling the interrupt on compare.   
0x1: If the autoWB_drop_cntreg bits are not modified before enabling the hmi_intr, autoWB internal counter=0 and autoWB_dop_cnt =1, serr compare interrupt will not occur. Default after reset.
Nonzero: if autoWB internal counter == autoWB_drop_cnt  == nonzero will create a serr compare interrupt. 
When the compare matches, autoWB_drop_flg will be set.
RW 0x1