AUTOWB_CORRADDR
This register shows the address of the current autoWB correction SBE.
Module Instance | Base Address | Register Address |
---|---|---|
ecc_hmc_ocp_slv_block | 0xFFCFB000 | 0xFFCFB138 |
Offset: 0x138
Access: RO
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
SWBADDRESS 0x0 |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
SWBADDRESS 0x0 |
AUTOWB_CORRADDR Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
31:0 | SWBADDRESS | recent autoWB correction address. This register shows the address of the current autoWB correction single-bit error. This address is logged when a new serr_req is generated to the system. This is gated by the single-bit error interrupt enable and ecc_en. Note that when a single-bit error occurs, an address is logged regardless of whether auto-correction is enabled or not. If you have not enabled auto-correction, this register can be ignored. |
RO | 0x0 |