SERRADDRA

         This register shows the address of PORTA current single-bit error. RAM size will determine the maximum number of address bits.
      
Module Instance Base Address Register Address
ecc_emac0_rx_ecc_registerBlock 0xFF8C0800 0xFF8C0830
ecc_emac1_rx_ecc_registerBlock 0xFF8C1000 0xFF8C1030
ecc_emac2_rx_ecc_registerBlock 0xFF8C1800 0xFF8C1830

Offset: 0x30

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

Address

0x0

SERRADDRA Fields

Bit Name Description Access Reset
11:0 Address
Recent single-bit error address.
RO 0x0