gmacgrp_flow_control
<b> Register 6 (Flow Control Register) </b>
The Flow Control register controls the generation and reception of the Control (Pause Command) frames by the MAC's Flow control module. A Write to a register with the Busy bit set to '1' triggers the Flow Control block to generate a Pause Control frame. The fields of the control frame are selected as specified in the 802.3x specification, and the Pause Time value from this register is used in the Pause Time field of the control frame. The Busy bit remains set until the control frame is transferred onto the cable. The Host must make sure that the Busy bit is cleared before writing to the register.
Module Instance | Base Address | Register Address |
---|---|---|
i_emac_emac0 | 0xFF800000 | 0xFF800018 |
i_emac_emac1 | 0xFF802000 | 0xFF802018 |
i_emac_emac2 | 0xFF804000 | 0xFF804018 |
Size: 32
Offset: 0x18
Access: RW
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
pt RW 0x0 |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
reserved_15_8 RO 0x0 |
dzpq RW 0x0 |
reserved_6 RO 0x0 |
plt RW 0x0 |
up RW 0x0 |
rfe RW 0x0 |
tfe RW 0x0 |
fca_bpa RW 0x0 |
gmacgrp_flow_control Fields
Bit | Name | Description | Access | Reset | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31:16 | pt |
Pause Time This field holds the value to be used in the Pause Time field in the transmit control frame. If the Pause Time bits is configured to be double-synchronized to the (G)MII clock domain, then consecutive writes to this register should be performed only after at least four clock cycles in the destination clock domain. |
RW | 0x0 | ||||||||||
15:8 | reserved_15_8 |
Reserved |
RO | 0x0 | ||||||||||
7 | dzpq |
Disable Zero-Quanta Pause When this bit is set, it disables the automatic generation of the Zero-Quanta Pause Control frames on the de-assertion of the flow-control signal from the FIFO layer (MTL or external sideband flow control signal sbd_flowctrl_i/mti_flowctrl_i). When this bit is reset, normal operation with automatic Zero-Quanta Pause Control frame generation is enabled.
|
RW | 0x0 | ||||||||||
6 | reserved_6 |
Reserved |
RO | 0x0 | ||||||||||
5:4 | plt |
Pause Low Threshold This field configures the threshold of the PAUSE timer at which the input flow control signal mti_flowctrl_i (or sbd_flowctrl_i) is checked for automatic retransmission of PAUSE Frame. The threshold values should be always less than the Pause Time configured in Bits[31:16]. For example, if PT = 100H (256 slot-times), and PLT = 01, then a second PAUSE frame is automatically transmitted if the mti_flowctrl_i signal is asserted at 228 (256 - 28) slot times after the first PAUSE frame is transmitted. The following list provides the threshold values for different values: - 00: The threshold is Pause time minus 4 slot times (PT - 4 slot times). - 01: The threshold is Pause time minus 28 slot times (PT - 28 slot times). - 10: The threshold is Pause time minus 144 slot times (PT - 144 slot times). - 11: The threshold is Pause time minus 256 slot times (PT - 256 slot times). The slot time is defined as the time taken to transmit 512 bits (64 bytes) on the GMII or MII interface.
|
RW | 0x0 | ||||||||||
3 | up |
Unicast Pause Frame Detect A pause frame is processed when it has the unique multicast address specified in the IEEE Std 802.3. When this bit is set, the MAC can also detect Pause frames with unicast address of the station. This unicast address should be as specified in the MAC Address0 High Register and MAC Address0 Low Register. When this bit is reset, the MAC only detects Pause frames with unique multicast address. Note: The MAC does not process a Pause frame if the multicast address of received frame is different from the unique multicast address.
|
RW | 0x0 | ||||||||||
2 | rfe |
Receive Flow Control Enable When this bit is set, the MAC decodes the received Pause frame and disables its transmitter for a specified (Pause) time. When this bit is reset, the decode function of the Pause frame is disabled.
|
RW | 0x0 | ||||||||||
1 | tfe |
Transmit Flow Control Enable In the full-duplex mode, when this bit is set, the MAC enables the flow control operation to transmit Pause frames. When this bit is reset, the flow control operation in the MAC is disabled, and the MAC does not transmit any Pause frames. In half-duplex mode, when this bit is set, the MAC enables the back-pressure operation. When this bit is reset, the back-pressure feature is disabled.
|
RW | 0x0 | ||||||||||
0 | fca_bpa |
Flow Control Busy or Backpressure Activate This bit initiates a Pause Control frame in the full-duplex mode and activates the backpressure function in the half-duplex mode if the TFE bit is set. In the full-duplex mode, this bit should be read as 1'b0 before writing to the Flow Control register. To initiate a Pause control frame, the Application must set this bit to 1'b1. During a transfer of the Control Frame, this bit continues to be set to signify that a frame transmission is in progress. After the completion of Pause control frame transmission, the MAC resets this bit to 1'b0. The Flow Control register should not be written to until this bit is cleared. In the half-duplex mode, when this bit is set (and TFE is set), then backpressure is asserted by the MAC. During backpressure, when the MAC receives a new frame, the transmitter starts sending a JAM pattern resulting in a collision. This control register bit is logically ORed with the mti_flowctrl_i input signal for the backpressure function. When the MAC is configured for the full-duplex mode, the BPA is automatically disabled.
|
RW | 0x0 |