ssc
Spread Spectrum Clocking (SSC) Control and Status Registers.
Module Instance | Base Address | Register Address |
---|---|---|
i_clk_mgr_perpllgrp | 0xFFD1007C | 0xFFD100C8 |
Size: 32
Offset: 0x4C
Access: RO
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
stat RO 0x0 |
Reserved |
en 0x0 |
ssc Fields
Bit | Name | Description | Access | Reset | ||||||
---|---|---|---|---|---|---|---|---|---|---|
8 | stat |
Indicates whether SSC is running. 1—SSC is active/enabled. Will only go to 1 once ictl_pll_freqgen_ssc_en_a has been asserted to 1. HP PLL output is at a SSC frequency. 0—SSC is disabled and that the HP PLL output frequency has returned to nominal frequency.
|
RO | 0x0 | ||||||
0 | en |
Enables/Disables SSC. 1—SSC is enabled (HP PLL output is running at spread spectrum mode) 0—SSC is disabled (HP PLL output will be at the nominal frequency)
|
not specified | 0x0 |