ECC_RDataecc0bus

         The msb bit for the register is configured based on DAT parameter (RAM word size). Unimplemented bytes of this register will be reserved.
      
Module Instance Base Address Register Address
i_ecc_aps_ram_ecc_registerBlock 0xFF8CC000 0xFF8CC064

Size: 32

Offset: 0x64

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

ECC_RDataecc3BUS

0x0

ECC_RDataecc2BUS

0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

ECC_RDataecc1BUS

0x0

ECC_RDataecc0BUS

0x0

ECC_RDataecc0bus Fields

Bit Name Description Access Reset
31:24 ECC_RDataecc3BUS
Eccdata will be read to this register field.
RO 0x0
23:16 ECC_RDataecc2BUS
Eccdata will be read to this register field.
RO 0x0
15:8 ECC_RDataecc1BUS
Eccdata will be read to this register field.
RO 0x0
7:0 ECC_RDataecc0BUS
Eccdata will be read to this register field.
RO 0x0