load_wait_cnt
Wait count value for Load operation
Module Instance | Base Address | Register Address |
---|---|---|
i_nand_config | 0xFFB80000 | 0xFFB80020 |
Size: 32
Offset: 0x20
Access: RW
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
value RW 0x1F4 |
load_wait_cnt Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
15:0 | value |
Number of clock cycles after issue of load operation before Cadence NAND Flash Controller polls for status. This values is of relevance for status polling mode of operation and has been provided to minimize redundant polling after issuing a command. After a load command, the first polling will happen after this many number of cycles have elapsed and then on polling will happen every intmon_cyc_cnt cycles. The default values is equal to the default value of intmon_cyc_cnt. |
RW | 0x1F4 |