load_wait_cnt

         Wait count value for Load operation 
      
Module Instance Base Address Register Address
i_nand_config 0xFFB80000 0xFFB80020

Size: 32

Offset: 0x20

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

value

RW 0x1F4

load_wait_cnt Fields

Bit Name Description Access Reset
15:0 value
Number of clock cycles after issue of load operation before 
                                Cadence NAND Flash Controller polls for status. This values is of
                                relevance for status polling mode of operation and has been
                                provided to minimize redundant polling after issuing a command.
                                After a load command, the first polling will happen after this many
                                number of cycles have elapsed and then on polling will happen every
                                intmon_cyc_cnt cycles. 
                                 The default values is equal to the 
                                 default value of intmon_cyc_cnt.
                               
RW 0x1F4