probe_ccu_main_Probe_TraceAlarmEn

         
      
Module Instance Base Address Register Address
i_noc_ccu_ios_probe_ccu_main_Probe 0xFFD22400 0xFFD22418

Size: 32

Offset: 0x18

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

TRACEALARMEN

RW 0x0

probe_ccu_main_Probe_TraceAlarmEn Fields

Bit Name Description Access Reset
2:0 TRACEALARMEN
Register TraceAlarmEn controls which lookup table or filter can set the TraceAlarm signal output once the trace alarm status is set. The number of bits in register TraceAlarmEn is determined by the value set for parameter nFilter + 1.Bit nFilter controls the lookup table output, and bits nFilter:0 control the corresponding filter output. When parameter nFilter is set to None, TraceAlarmEn is reserved.
RW 0x0