TIMER1CURRENTVAL

         Name: Timer1 Current Value
  Size: 8-32 bits
  Address Offset: 4
  Read/Write Access: Read
      
Module Instance Base Address Register Address
i_timer_sys_0_DW_apb_timers_addr_block 0xFFD00000 0xFFD00004
i_timer_sys_1_DW_apb_timers_addr_block 0xFFD00100 0xFFD00104

Size: 32

Offset: 0x4

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

TIMER1CURRENTVAL

RO 0x0

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

TIMER1CURRENTVAL

RO 0x0

TIMER1CURRENTVAL Fields

Bit Name Description Access Reset
31:0 TIMER1CURRENTVAL
Current Value of Timer1. This register is supported only
  when timer_1_clk is synchronous to pclk. Reading this
  register when using independent clocks results in an
  undefined value.
RO 0x0