TIMER1CURRENTVAL
Name: Timer1 Current Value
Size: 8-32 bits
Address Offset: 4
Read/Write Access: Read
Module Instance | Base Address | Register Address |
---|---|---|
i_timer_sys_0_DW_apb_timers_addr_block | 0xFFD00000 | 0xFFD00004 |
i_timer_sys_1_DW_apb_timers_addr_block | 0xFFD00100 | 0xFFD00104 |
Size: 32
Offset: 0x4
Access: RO
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
TIMER1CURRENTVAL RO 0x0 |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
TIMER1CURRENTVAL RO 0x0 |
TIMER1CURRENTVAL Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
31:0 | TIMER1CURRENTVAL |
Current Value of Timer1. This register is supported only when timer_1_clk is synchronous to pclk. Reading this register when using independent clocks results in an undefined value. |
RO | 0x0 |