probe_ccu_main_Probe_Counters_3_Val

         
      
Module Instance Base Address Register Address
i_noc_ccu_ios_probe_ccu_main_Probe 0xFFD22400 0xFFD2257C

Size: 32

Offset: 0x17C

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

COUNTERS_3_VAL

RO 0x0

probe_ccu_main_Probe_Counters_3_Val Fields

Bit Name Description Access Reset
15:0 COUNTERS_3_VAL
Register Val is a read-only register that is always present. The register containsthe statistics counter value either pending StatAlarm output, or when statisticscollection is suspended subsequent to triggers or signal statSuspend.
RO 0x0