devices_connected

         Number of Devices connected on one bank 
      
Module Instance Base Address Register Address
sdm_i_nand_config 0xFFA10000 0xFFA10250

Size: 32

Offset: 0x250

Access: RW

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

value

RW 0x0

devices_connected Fields

Bit Name Description Access Reset
2:0 value
Indicates the number of devices connected to a bank. At POR, the value loaded
                                   is the maximum possible devices that could be connected in this configuration. 
RW 0x0