re_2_re
Timing parameter between re high to re low (Trhz) for the next bank
Module Instance | Base Address | Register Address |
---|---|---|
i_nand_config | 0xFFB80000 | 0xFFB80290 |
Size: 32
Offset: 0x290
Access: RW
Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
Reserved |
|||||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved |
value RW 0x32 |
re_2_re Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
5:0 | value |
Signifies the number of bus interface clk_x clocks that should be introduced between read enable going high to a bank to the read enable going low to the next bank. The number of clocks is the function of device parameter Trhz and controller clock frequency. |
RW | 0x32 |