probe_ccu_main_Probe_TraceAlarmStatus

         
      
Module Instance Base Address Register Address
i_noc_ccu_ios_probe_ccu_main_Probe 0xFFD22400 0xFFD2241C

Size: 32

Offset: 0x1C

Access: RO

Important: The value of a reserved bit must be maintained in software. When you modify registers containing reserved bit fields, you must use a read-modify-write operation to preserve state and prevent indeterminate system behavior.
Bit Fields
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16

Reserved

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Reserved

TRACEALARMSTATUS

RO 0x0

probe_ccu_main_Probe_TraceAlarmStatus Fields

Bit Name Description Access Reset
2:0 TRACEALARMSTATUS
Register TraceAlarmStatus is a read-only register that indicates which lookup table or filter has been matched by a packet, independently of register TraceAlarmEn bit configuration. The number of bits in TraceAlarmStatus is determined by the value set for parameter nFilter + 1.When nFilter is set to None, TraceAlarmStatus is reserved.
RO 0x0