IC_ENABLE
Name: I2C Enable Register
Size: 18 bits
Address Offset: 0x6c
Read/Write Access: Read/Write
Bit 16 is read only when IC_SMBUS=0.
Bits 17 & 18 are read only when IC_SMBUS_SUSPEND_ALERT=0.
Module Instance | Base Address | Register Address |
---|---|---|
sdm_i_i2c_0_DW_apb_i2c_addr_block1 | 0xFF8D0100 | 0xFF8D016C |
sdm_i_i2c_1_DW_apb_i2c_addr_block1 | 0xFF8D0200 | 0xFF8D026C |
Size: 32
Offset: 0x6C
Access: RW
Bit Fields | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
RSVD_IC_ENABLE_2 RO 0x0 |
RSVD_SMBUS_ALERT_EN RO 0x0 |
RSVD_SMBUS_SUSPEND_EN RO 0x0 |
RSVD_SMBUS_CLK_RESET RO 0x0 |
||||||||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RSVD_IC_ENABLE_1 RO 0x0 |
RSVD_SDA_STUCK_RECOVERY_ENABLE RO 0x0 |
TX_CMD_BLOCK RW 0x0 |
ABORT RW 0x0 |
ENABLE RW 0x0 |
IC_ENABLE Fields
Bit | Name | Description | Access | Reset | ||||||
---|---|---|---|---|---|---|---|---|---|---|
31:19 | RSVD_IC_ENABLE_2 |
Reserved bits - Read Only |
RO | 0x0 | ||||||
18 | RSVD_SMBUS_ALERT_EN |
Reserved bits - Read Only |
RO | 0x0 | ||||||
17 | RSVD_SMBUS_SUSPEND_EN |
Reserved bits - Read Only |
RO | 0x0 | ||||||
16 | RSVD_SMBUS_CLK_RESET |
Reserved bits - Read Only |
RO | 0x0 | ||||||
15:4 | RSVD_IC_ENABLE_1 |
Reserved bits - Read Only |
RO | 0x0 | ||||||
3 | RSVD_SDA_STUCK_RECOVERY_ENABLE |
Reserved bits - Read Only |
RO | 0x0 | ||||||
2 | TX_CMD_BLOCK |
In Master mode 1'b1 blocks the transmission of data on I2C bus even if Tx FIFO has data to transmit. 1'b0 The transmission of data starts on I2C bus automatically, as soon as the first data is available in the Tx FIFO. Reset value : IC_TX_CMD_BLOCK_DEFAULT Dependencies: This Register bit value is applicable only when IC_TX_CMD_BLOCK =1 NOTE:In order to block the execution of Master commands, set the TX_CMD_BLOCK bit only when Tx FIFO is empty (IC_STATUS[2]==1) and Master is in Idle state (IC_STATUS[5] == 0). Then any further commands put in the Tx FIFO will not get executed until TX_CMD_BLOCK bit is unset.
|
RW | 0x0 | ||||||
1 | ABORT |
When set, the controller initiates the transfer abort. 0: ABORT not initiated or ABORT done 1: ABORT operation in progress The software can abort the I2C transfer in master mode by setting this bit. The software can set this bit only when ENABLE is already set; otherwise, the controller ignores any write to ABORT bit. The software cannot clear the ABORT bit once set. In response to an ABORT, the controller issues a STOP and flushes the Tx FIFO after completing the current transfer, then sets the TX_ABORT interrupt after the abort operation. The ABORT bit is cleared automatically after the abort operation. Reset value: 0x0
|
RW | 0x0 | ||||||
0 | ENABLE |
Controls whether the DW_apb_i2c is enabled. 0: Disables DW_apb_i2c (TX and RX FIFOs are held in an erased state) 1: Enables DW_apb_i2c Software can disable DW_apb_i2c while it is active. However, it is important that care be taken to ensure that DW_apb_i2c is disabled properly. When DW_apb_i2c is disabled, the following occurs: - The TX FIFO and RX FIFO get flushed. - Status bits in the IC_INTR_STAT register are still active until DW_apb_i2c goes into IDLE state. If the module is transmitting, it stops as well as deletes the contents of the transmit buffer after the current transfer is complete. If the module is receiving, the DW_apb_i2c stops the current transfer at the end of the current byte and does not acknowledge the transfer. In systems with asynchronous pclk and ic_clk when IC_CLK_TYPE parameter set to asynchronous (1), there is a two ic_clk delay when enabling or disabling the DW_apb_i2c. Reset value: 0x0
|
RW | 0x0 |