F-tile Architecture and PMA and FEC Direct PHY IP User Guide

ID 683872
Date 6/26/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

3.14.1.4. TX Error Injection

FHT PMA supports programmable number of error injection into the TX datapath.

To configure the TX datapath error injection, follow these steps:

  1. Write cfg_tx_err_inj_mask_cfg (0x45808[21:6]) to a value that you want to mask the TX data with and cause an error injection.
  2. Write cfg_tx_err_inj_mask_load (0x45810[0]) to 1'b1. (self-clears to 1'b0).
    Note: When you write a 1'b1 to this bit, the internal 128-bit error mask register shifts left by 16 bits, and the new 16-bit mask value replaces the LSB bits in the register. The 64-bit and 32-bit width modes use only the MSBs of the datapath. Therefore, you must load the mask multiple times to shift it into the MSB bits.
  3. Write err inj block-write cfg_tx_err_inj_en (0x45808[0]) to 1'b1 to enable error injection.
  4. Write cfg_tx_err_inj_trig (0x4580C[0]) to 1'b1 (self-clears to 1'b0) to inject the errors. Every time you write a 1'b1 to this bit, the 128 bit of datapath is XORed with 128 bits of error mask register.
  5. Repeat steps 1 and 2 to inject more errors.