Quartus® Prime Pro Edition User Guide: Debug Tools

ID 683819
Date 7/08/2024
Public
Document Table of Contents

2.4.6.9. Trigger Condition Flow Control

The Trigger Condition Flow Control allows you to define the relationship between a set of triggering conditions. Signal Tap logic analyzer Signal Configuration pane offers two flow control mechanisms for organizing trigger conditions:
  • Sequential Triggering—default triggering flow. Sequential triggering allows you to define up to 10 triggering levels that must be satisfied before the acquisition buffer finishes capturing.
  • State-Based Triggering—gives the greatest control over your acquisition buffer. Custom-based triggering allows you to organize trigger conditions into states based on a conditional flow that you define.

You can use sequential or state based triggering with either a segmented or a non-segmented buffer.